363-206-305 Detailed Level Procedure:
DLP-516
Issue 3, June 2000 Page 1 of 2
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Check Local Office Alarms
1.
!
CAUTION:
This test will interrupt service if it is performed without a CIT. If done with
a CIT, this test can be performed on an in-service system.
NOTE:
It is assumed that you were sent here by another procedure to test the
DDM-2000 FiberReach alarms.
Is a CIT available?
If YES, continue with Step 2.
If NO, proceed to Step 5.
2. Connect CIT to CIT connector on the User Panel.
3.
NOTE:
The "Commands and Reports" section of this user's manual under
TEST-ALM gives a description of the test-alm command.
Use the test-alm command to perform alarm tests. Note the audible
and visual alarm indications during the test.
4. Did the DDM-2000 FiberReach shelf pass the alarm tests?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, proceed to Step 14.
5.
NOTE:
It is assumed that the DDM-2000 FiberReach shelf is powered and
running with loops at the low-speed cross-connections and that the
high-speed terminations are either looped on themselves or connected in
an end-to-end looped configuration. It is also assumed that protection
circuit packs are installed and that no alarms or other diagnostic
indications are activated.
Unseat the service DS1/DS1PM, T1EXT, or HDSL circuit pack in LOW SPEED
slot LS-[ A-1, B-1, C-1, or D-1].
6. Wait 30 seconds.