363-206-305 Detailed Level Procedure:
Issue 3, June 2000 Page 1 of 12
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DLP-518
Make VT1.5 (DS1) or STS1 (DS3) Cross-Connections
Using CIT Single OC-3 or OC-12 Ring Configuration
1.
NOTE:
If you are not familiar with doing cross-connections using the CIT
commands, it is strongly suggested that you read
Cross-Connection
Provisioning
in the "Administration and Provisioning" section of this
manual. Also, read the description of the following commands in the
"Commands and Reports" section of this manual: ent-crs-sts1,
ent-crs-vt1, rtrv-crs-sts1, rtrv-crs-1, dlt-crs-sts1, and
dlt-crs-vt1.
NOTE:
You may have to log in to more than one node to get a complete map of
the network using the rtrv-map-network and rtrv-map-neighbor
command. If a drawing of the network is not provided with the work order,
it is recommended that you draw a simple schematic of the network
before making cross-connections. List the TID of each node and how
they are connected to each other. Figure 1 shows an example of a simple
schematic.
Log into any node in each ring in the network and use the
rtrv-map-network and rtrv-map-neighbor command to retrieve a
map of the network which lists all the systems and how they are connected to
each other. Sample output reports are shown in Figures 2, 3, and 4.