363-206-305 Detailed Level Procedure:
DLP-518
Issue 3, June 2000 Page 11 of 12
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Figure 9. Path Protected OC-12 Ring Network (T1 to T1) with VT1.5
Cross-Connections
a-1-1 to m-1-1-1
(ent-crs-vt1:a-1-1,m-1-1-1)
where:
a-1-1 = address ofT1 port 1, T1EXT circuit
pack 1 in LOW SPEED GROUP A
m-1-1-1 = address of STS #1 in
MAIN OLIU, VTG #1,VT #1
a-1-1 to m-1-1-1
(ent-crs-vt1:a-1-1,m-1-1-1)
where:
a-1-1 = address ofT1 port 1, T1EXT circuit
pack 1 in LOW SPEED GROUP A
m-1-1-1 = address of STS #1 in
MAIN OLIU, VTG #1,VT #1
OC-12 Path Switched Ring with
OC-3/FiberReach Shelves with OC-12 Optics
MAIN-1
MAIN-2
m-1
m-1
m-1
TSI
LS-A-2
LS-B-2
LS-C-2
LS-D-2
LS-A-1
LS-B-1
LS-C-1
T1EXT
OC-12
OC-12
OC-12 OC-12
LS-D-1
Node 5
DDM-2000
FiberReach OC-12
Node 1
DDM-2000 OC-12
Node 2
DDM-2000 OC-12
Node 4
DDM-2000 OC-12
Node 3
DDM-2000 OC-12
Node 6
DDM-2000 OC-12
Faceplate Connector
PassesThrough
Undropped STSs
m-1
m-12
m-12
m-12
m-12

Table of Contents