DLP-523
: Detailed Level Procedure 363-206-305
Page 6 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
22.
NOTE:
If line code (lc) parameters are generally set using the set-t1
command, the circuit pack switch settings will have no effect. The
rtrv-t1 command may be used to check line code settings.
Refer to Table C and Figure 1 and set the line code option switches, if required.
Note:
Switch 1, section 8 (
S1-8
) on the
BBF1/BBF1B DS1
is unused and ignored by the
system.
On the
BBF3 DS1PM
,
S1-8
must be set to OFF
.
Figure 1. DS1/DS1PM Option Settings
Table C DS1/DS1PM Line Code Settings
Line Code
Format
Switch S1 Settings
S1-4
(Port 1)
S1-5
(Port 2)
S1-6
(Port 3)
S1-7
(Port 4)
S1-8
(Note)
B8ZS OFF OFF OFF OFF
OFF
AMI ONONONON