DLP-523
: Detailed Level Procedure 363-206-305
Page 8 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
BBF6 T1EXT
25.
!
CAUTION:
In addition to primary lightning protection, an external Lightning and
Surge Secondary Protection Assembly (ED-8C783-30 or equivalent) is
required for
T1EXT
circuits used in outside plant applications.
NOTE:
To set switch to ON, depress rocker or slide switch toward side labeled
ON
in the figure. To set switch to OFF, depress rocker or slide switch toward
side labeled
OFF
in the figure.
Figure 2. T1EXT Option Settings
NOTE:
It is recommended that a policy be established to set line coding either
using the option switches OR using the set-t1 command. If line code (lc)
parameters are set using the set-t1 command, the circuit pack switch
settings will have no effect. The rtrv-t1 command may be used to check
line code settings.
Connector
Edge
5
Component Side
S1
OFF
ON
4321