363-206-305 Detailed Level Procedure:
DLP-526
Issue 3, June 2000 Page 13 of 18
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Figure 9. Example of Single Homing OC-3/OC-1 Cross-connections
EC-1
DS1
DS1
a-1-1 to m-1-1-1
(ent-crs-vt1:a-1-1,m-1-1-1)
where:
a-1-1 = address ofVT1.5 channel
in STS1E circuit pack in group A
m-1-1-1 = address of STS #1
in MAIN OLIU, VTG #1,VT #1
a-1-1 to m-1-1-1
(ent-crs-vt1:a-1-1,m-1-1-1)
where:
a-1-1 = address of DS1 circuit pack 1
in LS group A, DS1 port #1
m-1-1-1 = address of STS #1
in MAIN OLIU, VTG #1,VT #1
a-1-1-1 to m-1-1-1
(ent-crs-vt1:a-1-1-1,m-1-1-1)
where:
a-1-1-1 = address of OC-1 line 1,
VTG #1,VT1.5 channel
VT #1, in OLIU circuit pack
in FUNCTION UNITS
group A
m-1-1-1 = address of STS #1
in MAIN OLIU, VTG #1,VT #1
LS-A-1
LS-A-2
LS-B-1
LS-B-2
LS-C-1
LS-C-2
LS-D-1
LS-D-2
Node 1
DDM-2000 OC-3
Node 2
DDM-2000 OC-3
Node 4
DDM-2000 OC-3
Node 3
DDM-2000 OC-3
Node 5
DDM-2000 OC-3