363-206-305 Detailed Level Procedure:
DLP-528
Issue 3, June 2000 Page 1 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Make VT1.5 (DS1) Cross-Connections Using CIT
Stand Alone OC-1 Ring Configuration
1.
NOTE:
This procedure may also be found in 363-206-285,
DDM-2000 OC-3
Multiplexer, TARP Release 13 and Later, User/Service Manual (TOP) -
Volume II
.
NOTE:
If you are not familiar with doing cross-connections using the CIT
commands, it is strongly suggested that you read
Cross-Connection
Provisioning
in the "Administration and Provisioning" section of this
manual. Also, read the description of the following commands in the
"Commands and Reports" section of this manual: ent-crs-vt1.
NOTE:
You will have to log in to more than one node in each ring to get a
complete map of the network using the rtrv-map-network and
rtrv-map-neighbor command. If a drawing of the network is not
provided with the work order, it is recommended that you draw a simple
schematic of the network before making cross-connections.
Make a simple drawing of the network and list the TID of each node and
how they are connected to each other. Figure 1 shows an example of a
simple schematic.
Log in to any node in the ring and use the rtrv-map-network and/or
rtrv-map-neighbor command to retrieve a map of the network which lists
all the systems and how they are connected to each other. Sample output
reports are shown in Figures 2, 3, and 4.