DLP-530
: Detailed Level Procedure 363-206-305
Page 12 of 14 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
11. At both terminating (drop) nodes of the circuit being established, use the
ent-crs-( ): command to make the terminating cross-connections at OC-3
nodes (for example at the OC-3 Node 3 in Figures 9 and 10,
ent-crs-vt1:m-1-2-1,b-2-1:cct=twoway).
12. At the host FT-2000 or WaveStar OC-48/192 ring node sites, make proper
cross-connections.
13. Use the rtrv-crs-vt1: or rtrv-crs-sts1: command to verify that the
proper connections have been made. If an improper cross-connection is made,
use the dlt-crs-vt1: or dlt-crs-sts1: command to delete the improper
cross-connection and reenter the cross-connection.
14. At DDM-2000 OC-3 or FiberReach terminating nodes equipped with
BBG4B
DS3
circuit packs, use the set-trace-sts1 command to verify the proper
cross-connect path of a STS-1 cross-connected STS-1 signal.
15. After all cross-connections are made, use the rtrv-alm: command to verify
no alarms are present.
16. If DS3 cross-connections have been established and the terminating nodes
are equipped with
BBG4 DS3
circuit packs, use set-trace-sts1 command
to check integrity of cross-connect path.
Reference: DLP-544
17. If ne-acty, inc. VT AIS, inc. STS1 AIS, inc. VT unequipped, or
inc. STS1 unequipped alarms are present, look for missing or improperly
made cross-connections. Use
TAP-118
to locate missing cross-connections, if
required.