363-206-305 Detailed Level Procedure:
Issue 3, June 2000 Page 1 of 2
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DLP-531
Retrieve Generic Software Version ID
1. Is a CIT available?
If YES, continue with Step 2.
If NO, proceed to Step 5.
2. Connect CIT to User Panel and establish session.
Reference: DLP-521
3. Use the rtrv-eqpt:sysctl command to retrieve generic software version
number.
Response: System outputs an
Equipage and Version Report
which
contains the program version presently loaded into the
system.
4. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
5.
NOTE:
When the ACO button is depressed, all LEDs and the 7-segment display
on the SYSCTL light. If the ACO button is released within 2 seconds, the
LED test completes and the 7-segment display and all LEDs will revert to
normal operation. If the ACO button is depressed longer than 2 seconds,
the 7-segment display goes blank for 2 seconds and then each digit of
the generic software version code is scrolled through the display. The
LEDs remain lit while the code is being displayed. When the ACO button
is released, the LEDs remain lit until the full software version code is
displayed. If the ACO button is still depressed when the software version
code has completed cycling, the display goes blank for 2 seconds and
starts cycling through the software version code again. This continues as
long as the ACO button is depressed. When the ACO button is released
the cycle will complete and the display and all LEDs go to normal
operation.