363-206-305 Detailed Level Procedure:
DLP-544
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
13. Indications are that the Incoming Path Trace string message (INCTRC) does
not match the Expected Path Trace string message (EXPTRC) - (Status:
MISMATCH). Verify that the path string entered as the Expected Incoming
Path Trace (EXPTRC) at this node matches exactly the Outgoing Path Trace
string (TRC) entered at the other terminating node circuit packs. Verify cross
connections and terminating addresses at all nodes. Repeat this test from
Step 9.
14. Has the rtrv-trace-sts1:address command been performed at both
terminating ends?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, continue with Step 15.
15. Log out of remote location. Repeat this test from Step 9 for the other
terminating end.