DLP-545
: Detailed Level Procedure 363-206-305
Page 4 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
10. Use the following command to perform a DS3 transmission test in the demux
direction to test the DS3 loop in the DSX direction:
test-trmsn-t3:
address
:dirn=demux:dur=( );
Where
address
= address identifier of the DS3 signal.
dirn = direction of the test. If dirn=demux, direction is
toward fiber.
dur = duration of the test in minutes (1-120); default is 1.
11. Was the test successful (error free)?
If
YES
, continue with
Step 12
.
If
NO
, proceed to
Step 34
.
Figure 2. Transmission Test of DS3 Signal in DEMUX Direction
12. Is this the first service being placed on the group and is a protection DS3
circuit pack installed?
If
YES
, continue with
Step 13
.
If
NO
, proceed to
Step 17
.
DSX
Test Signal
Internal
Demultiplexing Direction
Monitor
NEAR END
Loop
Multiplexing Direction
DSX