363-206-305 Circuit Order:
NTP-003
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
10. Check the narrowband shelf indicators by pressing the LED TEST
button on the DSXBIU.
Requirement: All LEDs light on the DSXBIU, PCU, RGU, POTS
Channel Units (CUs) and CDTU.
11. Verify the alarm reporting system by removing the RGU.
CONFIG and NE LED lights on the DSXBIU.
FE and MJ alarms at the NBS.
12. Reinstall RGU.
Requirement: All alarms clear.
13. STOP. YOU HAVE COMPLETED THIS PROCEDURE.