TAD-100
: Trouble Clearing 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
N
ARROWBAND
S
HELF
SLC
-2000 Server Alarm Summary
DSXBIU Alarm Summary
FAIL
The
SLC
-2000 Server pack has failed self-diagnostic
tests.
CLF
Carrier line fail, communication with the NBS is lost. Path
for DS1 may be interrupted.
CONFIG
Placement of a channel unit in the wrong slot or an error
in the SLOT ALLOCATION option setting on the
SLC
-2000 Server channel unit (363-208-001,
SLC-2000
Access User/Service Manual
). Correct placement or
SLOT ALLOCATION option setting to clear
CONFIG
alarm. If the
SLC
-2000 Server is installed per work order,
record the digroup channel unit equipage and refer the
trouble to the engineering center. If
CONFIG
and
SLC
-2000 are both on, the channel unit installation
trouble is at the NBS.
FAIL
The
DSXBIU
circuit
pack has failed self-diagnostic tests.
CLF
Communication with the
SLC
-2000 Server is lost.
CONFIG
Placement of a channel unit in the wrong slot or an error in
the SLOT ALLOCATION switch setting on the
SLC
-2000
Server channel unit. Correct channel unit placement or
SLOT ALLOCATION option setting to clear
CONFIG
alarm. If
CONFIG
and
FE
are both on, the channel unit
installation trouble is at the RT
SLC
-2000. If
CONFIG
and
NE
are both on, the channel unit installation trouble is at
the
SLC
-2000.
Note:
The
CONFIG
LED on
DSXBIU
will flash while a
software download is in progress. This is not considered
a trouble condition.
FE
Trouble with SLC-2000 Server or any equipment in
between.
NE
Trouble with equipment in the NBS.