363-206-305
Circuit Pack Descriptions
Issue 3 June 2000
7-33
Control Circuitry
7
The BBG4/BBG4B DS3 circuit pack interfaces with the SYSCTL via the intra-shelf
control bus. Redundancy in the intra-shelf control bus assures the level of control
required to perform protection switching and alarming of a faulty circuit pack. The
BBG4/BBG4B DS3 provides maintenance elements for reporting the status of the
circuit pack, status of the incoming STS-1 and DS3 signals, as well as the circuit
pack inventory information (
CLEI
code, date of manufacture, etc.). These
maintenance elements are used by the SYSCTL for fault detection and isolation.
Conversely, the BBG4/BBG4B DS3 responds to control signals from the SYSCTL
(such as active and fault LED controls).
Protection Circuitry
7
Optional 1x1 nonrevertive BBG4/BBG4B DS3 circuit pack protection is provided.
Switch points for the STS-1 side of the DS3 are located on the OLIU circuit packs.
Switch points for the DS3 side are implemented with relays on the BBG4/BBG4B
DS3 circuit pack. To ensure that the relays can be operated when the circuit pack
fails, the relay is controlled by the SYSCTL, via the control interfaces. Also, if
power to the board is lost, the relay switches autonomously to the standby state.
When a new board is inserted, it defaults to the standby state until provisioned
active by the SYSCTL.
On the DS3 side, a single DS3 input from a DSX-3 is sent to both the active and
standby BBG4/BBG4B DS3 circuit packs. Only the active unit selects the DS3
input. The SYSCTL supervises the state of the active and standby units so that
the relay state of each is always the inverse of the other. The hybrid on the active
unit splits the DS3 input signal and sends it to the standby unit and to its own
receiver. To implement a protection switch on the DS3 side, the SYSCTL switches
the relays on each unit to their opposite state.
When a BBG4/BBG4B DS3 is removed, shorting contacts on the backplane
connector operate so that the DS3 input signal from its companion unit is returned
for proper termination.
Fault Detection Circuitry
7
The BBG4/BBG4B DS3 circuit pack has in-service and out-of-service built-in test
capability. In-service testing is continuous and errors are reported when they
occur to the SYSCTL via the intra-shelf control bus. An out-of-service test is
performed whenever the BBG4/BBG4B DS3 circuit pack is inserted or recovers
from a transient failure.
The incoming DS3 signal is monitored for bipolar threshold crossings in excess of
10
-3
or 10
-6
, LOS, DS3 OOF, and DS3 AIS. Incoming STS-1 signals are monitored
for STS AIS, STS LOP, and yellow and are also monitored for DS3 OOF and AIS.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FiberReach DDM-2000 and is the answer not in the manual?

Lucent Technologies FiberReach DDM-2000 Specifications

General IconGeneral
BrandLucent Technologies
ModelFiberReach DDM-2000
CategoryMultiplexer
LanguageEnglish

Related product manuals