363-206-305
Circuit Pack Descriptions
7-74
Issue 3 June 2000
Control Functions
7
The major control functions of the 22-type circuit packs are as follows:
Process transport overhead
Store inventory information (
CLEI
code, date of manufacture, etc.)
Maintenance Signal Functions
7
The major maintenance signal functions of the 22-type circuit packs are as
follows:
Insert STS-1 path AIS
For 22-type, insert and detect OC-3/IS-3 line AIS
Insert path unequipped signal
Insert and detect line FERF
For 22-type, detect OC-3/IS-3 line failures (LOS, LOF, AIS, and BER)
For 22-type, detect OC-3/IS-3 line signal degrade BER.