363-206-305
Technical Specifications
10-24
Issue 3 June 2000
Table 10-9 lists the 26G2-U OLIU specifications.
Table 10-9. 26-Type OLIU Specifications
System Information:
26-Type
Terminal Equipment Identification 26-type OLIU
Optical Line Rate (Mb/s) 51.84 Mb/s
Optical Line Coding Scrambled NRZ
Optical Wavelength 1310 nm
Performance Not applicable
Transmitter Information:
Optical Device Temperature
Controller
No TEC
FDA Classification Class I
Optical Source InGaAsP Laser, MLM
*
Structure
* A higher quality SLM laser may be used instead of the MLM laser.
Faceplate Optical Connector UOC buildout assembly
Single Mode
The universal optical connector (UOC) buildout assembly consists of a
faceplate-mounted block assembly and either 0 dB, 5 dB, 10 dB, or 15 dB
buildout in either ST,
SC,
or FC-type connectors. FC-type connectors are
not available for multimode cabling.
Receiver Information:
Optical Device Temperature
Controller
None
Optical Detector InGaAsP PIN
Faceplate Optical Connector UOC buildout assembly
Multi-Mode