363-206-305
Technical Specifications
10-46
Issue 3 June 2000
Transient Performance
10
Power Loss Restart
10
After system shutdown due to power loss, the system will begin error free
transmission within one minute of restoration of power.
Transmission Start-Up on Signal Application
10
The system, after having no signal applied for greater than one minute at the
DSX-n interface, will begin error free transmission within five seconds of the
reapplication of a signal.
Delay
10
Table 10-22 lists the worst-case measured 1-way transmission delay within a
DDM-2000 FiberReach Multiplexer.
Table 10-22. DDM-2000 OC-1 Transmission Delay in Microseconds
Mode (High-Speed) DS1 Low-Speed Interface
Ring (OC-1)* 100
*
Ring delay is based on an OC-1 to low-speed DS1.