363-206-305
Technical Specifications
Issue 3 June 2000
10-67
Table 10-29. Transmission Specifications — VF Channel Units with Fixed 
Settings — 
Continued
 
  Value (Measured at 25
°
 
C
) 
Parameter POTS 
SPOTS
®
 Unit
 
Coin 
Intermodulation Distortion 
(
−
13 dBm0 Input)
A-B (R2) Product: > 43 dB 
2A-B (R3) Product: > 44 dB
Single Frequency Distortion
(0-12 kHz 0 dBm0) 
< 
−
28 dBm0 
Impulse Noise ¶ 
≤
 15 Counts in 15 Minutes 
Overload at COT and HDT 
≥
 
+
 3 dBm0 
Longitudinal Balance at the HDT ** 
(Minimum)
200 Hz, 500 Hz, 1,000 Hz: 
≥
 58 dB 
3,000 Hz: 
≥
 53 dB
* Measured as insertion loss between 900-ohm terminations. R
EXT
 includes 
both the loop resistance and the station set resistance. Actual threshold 
value for R
EXT
 is 1100 ohms 
±
100 ohms. 
† Measured as the ICL with the HDT terminated in 600 ohms and with the 
COT terminated in 900 ohms. 
‡ Measured with respect to 900 ohms and 2.16 
µ
F with the 4-wire path 
broken or with the other end terminated in 1,100 ohms in parallel with 0.03 
µ
F. 
§ Measured with respect to 600 ohms and 2.16 
µ
F with the 4-wire path 
broken or with the other end terminated in 900 ohms and 2.16 
µ
F. 
¶ Measured with a holding tone of 
−
13 dBm0 and a threshold of 59 
dBrnC0. 
** Measured by Institute of Electrical and Electronics Engineers (IEEE) 
method 455-1976.