4. Conduct a Preliminary E-Lift Test:
After all parameters have been configured in steps 2 and 3, the E-Lift function must be tested to ensure it can
raise and lower a load properly. Conduct the following steps to verify the E-Lift function:
a. Attach a test load to the hoist (rated capacity is recommended).
b. Raise the load approximately one foot above the floor.
c. Turn on the MFDI associated with E-Lift enable (H01-01 ~ H01-08 = 44).
d. Inspect the display on the keypad. The flashing title should alternate between “Emergency Lift” and the
present menu title, which confirms that the E-Lift function is active.
e. Perform a series of raise and lower commands and observe the test load.
f. If steps 4.a through 4.e were successful, turn off the E-Lift MFDI and return the hoist to normal operations.
DANGER
If any undesired motions occur while E-Lift is active, immediately remove any RUN commands, turn off the E-
Lift MFDI, and contact Magnetek.