5 Programming Advanced Features
5.1 Speed Parameters
The speed parameters control the speed frequencies, acceleration and deceleration characteristics, and reference
sources. Speed parameters included in this section are listed below:
B01 Speed References
B02 Reference Limits
B03 Sequence/Reference Source
B05 Acceleration/Deceleration
B08 Jump Frequencies
5.1.1 Speed References
Table 5-1: Speed Reference Settings
* Initial value is determined by X-Press Programming (Table 4-6 on page 59, Table 4-7 on page 60 or Table 4-8 on page 61).
Parameter Display Function Range Default
B01-01 Reference 1 Sets the Speed 1 frequency. 0.00–E01-04 Hz 15.00*
B01-02 Reference 2 Sets the Speed 2 frequency. 0.00–E01-04 Hz 30.00*
B01-03 Reference 3 Sets the Speed 3 frequency. 0.00–E01-04 Hz 60.00*
B01-04 Reference 4 Sets the Speed 4 frequency. 0.00–E01-04 Hz 0.00*
B01-05 Reference 5 Sets the Speed 5 frequency. 0.00–E01-04 Hz 0.00*
B01-06 Reference 6 Sets the Speed 6 frequency. 0.00–E01-04 Hz 0.00*
B01-07 Reference 7 Sets the Speed 7 frequency. 0.00–E01-04 Hz 0.00*
B01-08 Reference 8 Sets the Speed 8 frequency. 0.00–E01-04 Hz 0.00*
B01-09 Reference 9 Sets the Speed 9 frequency. 0.00–E01-04 Hz 0.00*
B01-10 Reference 10 Sets the Speed 10 frequency. 0.00–E01-04 Hz 0.00*
B01-11 Reference 11 Sets the Speed 11 frequency. 0.00–E01-04 Hz 0.00*
B01-12 Reference 12 Sets the Speed 12 frequency. 0.00–E01-04 Hz 0.00*
B01-13 Reference 13 Sets the Speed 13 frequency. 0.00–E01-04 Hz 0.00*
B01-14 Reference 14 Sets the Speed 14 frequency. 0.00–E01-04 Hz 0.00*
B01-15 Reference 15 Sets the Speed 15 frequency. 0.00–E01-04 Hz 0.00*
B01-16 Reference 16 Sets the Speed 16 frequency. 0.00–E01-04 Hz 0.00*
B01-17 Jog Reference Jog Control and Inching Control frequency
reference.
0.00–E01-04 Hz 6.00*
B01-18 Ref Priority
0 Digital Ref Only
1 Analog Ref Only
2 Higher RefSelect
Determines whether the digital or analog
frequency reference is used.
NOTE:
When
using Higher Reference Select, Infinitely
Variable should NOT be used (A01-04 = 3).
The two functions are not intended to work
in conjunction.
0–2 0*

Table of Contents

Other manuals for Magnetek IMPULSE G+ 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek IMPULSE G+ 4 Series and is the answer not in the manual?

Magnetek IMPULSE G+ 4 Series Specifications

General IconGeneral
BrandMagnetek
ModelIMPULSE G+ 4 Series
CategoryDC Drives
LanguageEnglish

Related product manuals