5.8.3 Maintenance History
Table 5-108: Clear History Parameter Settings
Parameter Display Function Range Default
O03-01 Elapsed Time Set Sets the value for the cumulative operation
time of the VFD in units of 10 hours.
Cumulative time can be viewed using
monitor Cumulative Operation Time (U04-
01). A setting of 30 = 300 hours
0–9999 x 10 hr 0
O03-02 Elapsed Time Run Selects how the cumulative timer will keep
track of the total operation time.
0, 1 1
0 Power-On Time Logs power-on time
1 Running Time Logs operation time when the VFD output is
active.
O03-03 Fan ON Time Set Sets the value of the Fan Operation Time
monitor (U04-03) in units of 10 hours. A
setting of 30 = 300 hours
0–9999 x 10 hr 0
O03-05 BusCap Maint Set Sets the value of the Maintenance Monitor
for the capacitors. See U04-05 to check
when the capacitors may need to be
replaced.
0–150% 0
O03-09 IGBT Maint Set Sets the value of the Maintenance Monitor
for the IGBTs. See U04-07 for IGBT
replacement times.
0–150% 0
O03-11 Fault Data Init Determines if Fault Trace (U02-xx) and
Fault History (U03-xx) parameters will be
cleared.
0, 1 0
0 No Reset Not cleared
1 Reset Resets the U02.xx and U03.xx fault history
data.
O03-12 kWh Monitor Init Determines if the monitor data (U04-10 and
U04-11) are reset.
0, 1 0
0 No Reset Not cleared.
1 Reset U04-10
O03-14 Count Hist Clear Determines which counter will be cleared.
After counters are cleared, initial value
(O03-14) is set to 0.
0–3 0
0 No Reset Not cleared.
1 Reset Runs Run commands counter is reset (U03-21
and U03-22).
2 OL/LC Count Clr Clears OL/LC Counters (U03-23).
3 Both Count Clr Clears Runs and OL/LC Counters.

Table of Contents

Other manuals for Magnetek IMPULSE G+ 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek IMPULSE G+ 4 Series and is the answer not in the manual?

Magnetek IMPULSE G+ 4 Series Specifications

General IconGeneral
BrandMagnetek
ModelIMPULSE G+ 4 Series
CategoryDC Drives
LanguageEnglish

Related product manuals