5.6.7 Analog Outputs
The IMPULSE
®
•G+ and VG+ Series 4 has two built-in analog outputs for the external monitoring of VFD
conditions. VFD analog output capabilities can be increased with the installation of an AO-A3 option.
Table 5-83: Analog Outputs Parameter Settings
Parameter Display Function Range Default
H04-01 Terminal FM Sel Assigns one of the following function
analog output parameters to Terminal FM.
Reference the U monitor group for output
function descriptions.
000–630 102
0 Not Used
101 Frequency Ref
102 Output Freq
103 Output Current
105 Motor Speed
106 Output Voltage
107 DC Bus Voltage
108 Output HP
109 Torque Reference
115 Term A1 Level
116 Term A2 Level
117 Term A3 Level
120 SFS Output
121 AI Opt Ch1 Level
122 AI Opt Ch2 Level
123 AI Opt Ch3 Level
129 Load Weight
130 SS Delta Speed
150 Hook Height
154 Input Pulse Mon
163 PG CH1 Freq
164 PG CH2 Freq
165 PG Output Freq
408 Heatsink Temp
416 Motor OL1 Level
417 Drive OL2 Level
601 Mot SEC Current
602 Mot EXC Current
603 ASR Input
604 ASR Output
605 Voltage Ref (Vq)