5.6.3 Digital Outputs
The IMPULSE
®
•G+ and VG+ Series 4 has three built-in multi-function digital outputs for indicating various
conditions. Digital output capabilities can be increased with the installation of an S4IO or DO-A3 option card. The
following table lists the function selections for the multi-function digital outputs.
Table 5-74: Digital Outputs Parameter Settings
* Initial value is determined by X-Press Programming (Table 4-6 on page 59, Table 4-7 on page 60 or Table 4-8 on page 61).
Parameter Display Function Range Default
H02-01 Term M0-M1 Sel Digital Output 1 Function
(See Table 5-75 on page 152.)
0–1FF *
H02-02 Term M2-M3 Sel Digital Output 2 Function
(See Table 5-75 on page 152.)
0–1FF *
H02-03 Term M5-M6 Sel Digital Output 3 Function
(See Table 5-75 on page 152.)
0–1FF *
H02-06 Wh Disp Units Watt Hour Output Unit Selection 0–4 0
0 0.1 kWh units
1 1 kWh units
2 10 kWh units
3 100 kWh units
4 1000 kWh units