5.2.18 Digital Input (DI-A3, S4I, or S4IO) Option Card Setup
Selects the digital input controls for either the DI-A3, S4I, or S4IO option when installed.
Table 5-34: Digital Input Setup Parameter Settings
* See Table 5-71 on page 148 for MFDI selections. The following input functions will not operate on an input option board: 20~20F, 31, 34, 35,
47, 80, or 81.
Parameter Display Function Range Default
C09-01 Digital In Sel Provides additional programmable MFDI 0–2, 5 0
0 Disabled No additional MFDI are being used.
1 Enabled S4IO S4IO or S4I card is installed
2 Enabled DI-A3 DI-A3 card is installed
5 Serial Modbus RTU using C09-02–C09-17
Parameter Display
Terminal Designation
Range Default
DI-A3 S4I S4IO
C09-02* DIO Terminal 1 0 I1 I1 00–FF 0F
C09-03* DIO Terminal 2 1 I2 I2 00–FF 0F
C09-04* DIO Terminal 3 2 I3 I3 00–FF 0F
C09-05* DIO Terminal 4 3 I4 I4 00–FF 0F
C09-06* DIO Terminal 5 4 - - 00–FF 0F
C09-07* DIO Terminal 6 5 - - 00–FF 0F
C09-08* DIO Terminal 7 6 - - 00–FF 0F
C09-09* DIO Terminal 8 7 - - 00–FF 0F
C09-10* DIO Terminal 9 8 - - 00–FF 0F
C09-11* DIO Terminal 10 9 - - 00–FF 0F
C09-12* DIO Terminal 11 A - - 00–FF 0F
C09-13* DIO Terminal 12 B - - 00–FF 0F
C09-14* DIO Terminal 13 C - - 00–FF 0F
C09-15* DIO Terminal 14 D - - 00–FF 0F
C09-16* DIO Terminal 15 E - - 00–FF 0F
C09-17* DIO Terminal 16 F - - 00–FF 0F