IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 148
Table 5-71: Multi-Function Digital Inputs (MFDI) selectable for H01-0x and C09-0x
Display Function
0 Multi-Step Ref 2 Multi-Step Reference 2
1 Multi-Step Ref 3 Multi-Step Reference 3
2 Multi-Step Ref 4 Multi-Step Reference 4
3 Multi-Step Ref 5 Multi-Step Reference 5
4 Speed Hold 2 Speed Hold 2 (2nd Step of Three-Step Infinitely Variable)
5 Accel Command Accel Command (2nd Step of Two-Step Inf. Var. or 3rd Step of Three-Step Inf. Var.)
6 Upper Lmt 1 N.O. Upper Limit - Slow Down; Normally Open. UL1 - blinking
7 Upper Lmt 2 N.O. Upper Limit - Stop; Normally Open. UL2 - blinking
8 Lower Lmt 1 N.O. Lower Limit - Slow Down; Normally Open. LL1 - blinking
9 Lower Lmt 2 N.O. Lower Limit - Stop; Normally Open. LL2 - blinking
A Upper Lmt 1 N.C. Upper Limit - Slow Down; Normally Closed. UL1 - blinking
B Upper Lmt 2 N.C. Upper Limit - Stop; Normally Closed. UL2 - blinking
C Lower Lmt 1 N.C. Lower Limit - Slow Down; Normally Closed. LL1 - blinking
D Lower Lmt 2 N.C. Lower Limit - Stop; Normally Closed. LL2 - blinking
E M-Speed Gain 1 Micro-Speed multiplier 1. Gain is set by parameter C02-01. (Priority over Micro-Speed 2)
F Not Used No function - Terminal is disabled.
10 M-Speed Gain 2 Micro-Speed multiplier 2. Gain is set by parameter C02-02.
11 Load Float 1 Load Float Hold - During run, Load Float will remain On and Fref is held at 0 Hz.
12 Weight Lmt N.C. Weighted Upper Limit - UL3. Stopping Method determined by C03-08.
13 Swift/Ultra-Lift Enable Ultra/Swift Lift Enable (C06-01 = 2). Not Available for Traverse Motion.
14 Alt T-Lim Gain Alternate Torque Limit Gain - C07-05. Use when Load Testing a Hoist.
15 Forward Jog Forward Jog (Uses B01-17 Reference)
16 Reverse Jog Reverse Jog (Uses B01-17 Reference)
17 Forward Inch Forward Inch
18 Reverse Inch Reverse Inch
19 Inch Repeat Inch Repeat
1A Acc/Dec 2 Acceleration/Deceleration Time Changeover 2 using B05-03 and B05-04
1B Acc/Dec 3 Acceleration/Deceleration Time Changeover 3 using B05-12 and B05-13
1C Acc/Dec 4 Acceleration/Deceleration Time Changeover 4 using B05-14 and B05-15
1D Digital Chngover Analog/Digital Reference Changeover; When B01-18 = 1 On: Digital
1F Run/Ref Src 1/2 Run/Ref Source 2 Switch - On: B03-15 / B03-16; Off: B03-01/B03-02
20 through 2F External Fault Selection (See Table 5-79 on page 157)
30 Program Lockout When input is OFF, parameter changes disabled except freq. reference (U01.01).
31 Local/Remote Sel Local/Remote Changeover. On: Local
32 Ext BaseBlk N.O. N.O.: Baseblock by ON.
33 Ext BaseBlk N.C. N.C.: Baseblock by OFF.
34 Spd/Trq Chngover Speed/Torque Control Changeover (ON: Torque Control)
35 Load Float 2 Zero Speed initiated. Manual Load Float Timed by C04-01.
36 Polarity Rev Polarity Reversing command for External Torque Control. On: Reverse Polarity
37 ASR Gain Switch On: Switches to ASR Gain 2 parameters - Forces D04-07.
38 Acc/Dec RampHold Speed Hold 1 - Accel/decel is stopped by ON, and frequency is held.
39 OH2 Alarm Signal External OH2 - VFD overheat prediction (OH2 is shown by ON.) (Alarm Only)

Table of Contents

Other manuals for Magnetek IMPULSE G+ 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek IMPULSE G+ 4 Series and is the answer not in the manual?

Magnetek IMPULSE G+ 4 Series Specifications

General IconGeneral
BrandMagnetek
ModelIMPULSE G+ 4 Series
CategoryDC Drives
LanguageEnglish

Related product manuals