EasyManua.ls Logo

Magnetek IMPULSE G+ 4 Series - Lower Limit;Upper Limit Bypass MFDI

Magnetek IMPULSE G+ 4 Series
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 90
5.2.10 Lower Limit/Upper Limit Bypass MFDI
The Limit Bypass allows for the following without the use of jumpers or re-programming parameters:
1. Ease of testing of the Weighted Upper Limit Switch (UL3) or re-homing the Height Measurement
function, and
2. To allow changing of the wire ropes, i.e. spooling all the rope off of the hoist drum.
NOTE: The momentary key-switch to operate this function should only be accessible to maintenance personnel,
not the crane operator. A functional description and usage procedure should be included in an
administrative control program to avoid confusion and potentially have the End of Travel Limit switches left
in a bypassed state during normal operation of the crane.
Table 5-26: Limit Bypass MFDI
× = Limit Bypass
Functions Bypassed
C09-0x or H01-0x settings will bypass the functions in the left most column
when the input is activated
73 74
Upper Limit 1 N.O. (MFDI = 06) ×
Upper Limit 2 N.O. (MFDI = 07) × ×
Lower Limit 1 N.O. (MFDI = 08) ×
Lower Limit 2 N.O. (MFDI = 09) × ×
Upper Limit 1 N.C. (MFDI = 0A) ×
Upper Limit 2 N.C. (MFDI = 0B) × ×
Lower Limit 1 N.C. (MFDI = 0C) ×
Lower Limit 2 N.C. (MFDI = 0D) × ×
UL2 detected by EPLS (C03-16) × ×
UL1 detected by EPLS (C03-17) ×
LL1 detected by EPLS (C03-18) ×
LL2 detected by EPLS (C03-19) × ×