IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 90
5.2.10 Lower Limit/Upper Limit Bypass MFDI
The Limit Bypass allows for the following without the use of jumpers or re-programming parameters:
1. Ease of testing of the Weighted Upper Limit Switch (UL3) or re-homing the Height Measurement
function, and
2. To allow changing of the wire ropes, i.e. spooling all the rope off of the hoist drum.
NOTE: The momentary key-switch to operate this function should only be accessible to maintenance personnel,
not the crane operator. A functional description and usage procedure should be included in an
administrative control program to avoid confusion and potentially have the End of Travel Limit switches left
in a bypassed state during normal operation of the crane.
Table 5-26: Limit Bypass MFDI
× = Limit Bypass
Functions Bypassed
C09-0x or H01-0x settings will bypass the functions in the left most column
when the input is activated
73 74
Upper Limit 1 N.O. (MFDI = 06) ×
Upper Limit 2 N.O. (MFDI = 07) × ×
Lower Limit 1 N.O. (MFDI = 08) ×
Lower Limit 2 N.O. (MFDI = 09) × ×
Upper Limit 1 N.C. (MFDI = 0A) ×
Upper Limit 2 N.C. (MFDI = 0B) × ×
Lower Limit 1 N.C. (MFDI = 0C) ×
Lower Limit 2 N.C. (MFDI = 0D) × ×
UL2 detected by EPLS (C03-16) × ×
UL1 detected by EPLS (C03-17) ×
LL1 detected by EPLS (C03-18) ×
LL2 detected by EPLS (C03-19) × ×