IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 162
H04-01 606 Voltage Ref (Vd) 000–630 102
607 ACR(q) Output
608 ACR(d) Output
611 Iq Reference
612 Id Reference
618 PG1 CounterValue
619 PG2 CounterValue
622 Zero Servo Pulse
625 ASR Out w/o Fil
626 FF Cont Output
627 FF Estimate SPD
H04-02 Terminal FM Gain Gain multiplier for Terminal FM -999.9–999.9% 100.0
H04-03 Terminal FM Bias Bias multiplier for Terminal FM -999.9–999.9% 0.0
H04-04 Terminal AM Sel Assigns one of the above functions to
Terminal AM
000–630 103
H04-05 Terminal AM Gain Gain multiplier for Terminal AM -999.9–999.9% 50.0
H04-06 Terminal AM Bias Bias multiplier for Terminal AM -999.9–999.9% 0.0
H04-07 FM Level Select Voltage output level of Terminal FM 0–2 0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA
H04-08 AM Level Select Voltage output level of Terminal AM 0–2 0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA Only available for 24 VDC interface card
Parameter Display Function Range Default