IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 117
During Run
If the motor is in motion when the Index function is turned ON, the VFD will decelerate to zero and hold the position
in Load Float. After a Run command is applied, the VFD will Index the load and hold the position in Load Float after
the Index is complete. The brake is set according to the No-Load Brake stop sequence when the Index function is
turned OFF.
NOTE: For best performance, enable Index after brake has released. Not recommended for double A4
applications.
NOTE: When either the Index Enable or Run Command is removed, the stop sequence will be initiated.
Table 5-43: Index Control Parameter Settings
Parameter Display Function Range Default
C13-03 Index Run Ref Index frequency Ref. (MFDI = 60) 0.01–60.00 Hz 0.10
C13-04 Index Revs Index motor revolutions
(F01-01 PPR = 1 Rev.)
0–65535 Rev 0
C13-05 Index Count Index fractional motor revolution.
4 pulses = 1 ppr of F01-01
0–65535 Pulses 100
C13-06 Index Rpt Delay Index Repeat Delay Time (Setting of 0.00
disables Index Repeat).
0.00–60.00 sec 0.00
C13-07 Index Complete Index Complete Width
(Quadrupled) for MFDO = 34.
Upper Limit range is dependent on the following
conditions: 32767 or (C13-04 *4 * encoder
PPR + C13-05 -1), whichever is smaller.
1 pulse = 1 ppr of F01-01
0–32767 10
C13-08 Index Zsv Gain Index Zero Servo Gain. 0–100 10
C13-09 Index ASR P Gain Index ASR P Gain. 0.00–300.00 30.00
C13-10 Index ASR I Time Index ASR Integral Time. 0.000–10.000 sec 0.200
C13-11 Acc/Dec Gain Index Accel/Decel Rate Gain. 0.0–5.0 1.0
C13-12 Index Brake Ctrl Configures brake behavior when indexing
(traverse only).
TRAV: 0–2
NLB: 0, 2
NLB: 2
else: 0
0 Open on Index Brake will open on Index Cmd and remain open
until Index Cmd is OFF. VFD is in Load Float
between runs.
1 Open on each Run Brake will open on Run cmd and close when run
is finished, or after Load Float in NLB.
2 Ltch Open on Run Brake will open on Run cmd and remain open
with VFD in Load Float until Index is turned off.

Table of Contents

Other manuals for Magnetek IMPULSE G+ 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek IMPULSE G+ 4 Series and is the answer not in the manual?

Magnetek IMPULSE G+ 4 Series Specifications

General IconGeneral
BrandMagnetek
ModelIMPULSE G+ 4 Series
CategoryDC Drives
LanguageEnglish

Related product manuals