IMPULSE
®
•G+ & VG+ Series 4 Technical Manual
November 2020
Page 138
F01-14 PG2 #Gear Teeth2
Sets the gear ratio between the motor shaft and the
encoder (PG).
A gear ratio of 1 will be used if F01-13 or F01-14 are
set to 0.
0–1000 0
F01-15 PG2 Output Ratio Sets the division ratio for the pulse monitor. 1–132 1
F01-16 PGO-2-H Delay time for PGO-2-H detection. A setting of 0
disables PGO-2-H detection. Channel 2 is associated
with slot CN5-B.
0–100 ms 15
F01-21 PG Fdbk Loss Sel Stopping method when PGO-1-S or PGO-2-S faults
are detected.
Traverse: 0–3
NLB: 1
1
0 Decel to Stop Decelerate to stop using the deceleration time in B05-
02.
1 Coast to Stop
2 Fast Stop Decelerate to stop using the deceleration time in B05-
08.
3 Alarm Only
F01-22 PGO-1-S Det Time PGO-1-S (CH1) disconnection detection time. A
setting of zero disables PGO-1-S detection.
0.0–10.0 sec 2.0
F01-23 PG Overspeed Sel Sets the stopping method when an overspeed (OS)
fault occurs.
Traverse: 0–3
NLB: 1
1
0 Decel to Stop Decelerate to stop using the deceleration time in
B05-02.
1 Coast to Stop
2 Fast Stop Decelerate to stop using the deceleration time in
B05-08.
3 Alarm Only
F01-24 PG Overspd Level Sets the overspeed detection level as a percentage of
the maximum output frequency.
0–120% 105
F01-25 PG Overspd Time Sets the time in seconds for an overspeed situation to
trigger a fault (oS).
0.0–2.0 sec 0.0
F01-26 PG Deviation Sel Stopping method at excessive speed deviation. Traverse: 0–7
NLB: 5
5
0 @Spd Agree-Decel Stops by deceleration time 1 - B05-02.
1 @Spd Agree-Coast Coast to stop.
2 @SpdAgree-F-Stop Decelerates by fast-stop B05-08.
3 @Spd Agree-Alm DEV displayed, operation continues.
4 @Run-Decel Stops by deceleration time 1 - B05-02.
5 @Run-Coast Coast to stop.
6 @Run-Fast Stop Decelerates by fast-stop B05-08.
7 @Run-Alarm Only DEV displayed, operation continues
F01-27 PG Deviate Level Sets the speed deviation detection level as a
percentage of the maximum output frequency.
0–50% 10
F01-28 PG Deviate Time Sets the time in seconds for a speed deviation
situation to trigger a fault DEV.
0.0–10.0 sec 0.3
Parameter Display Function Range Default

Table of Contents

Other manuals for Magnetek IMPULSE G+ 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek IMPULSE G+ 4 Series and is the answer not in the manual?

Magnetek IMPULSE G+ 4 Series Specifications

General IconGeneral
BrandMagnetek
ModelIMPULSE G+ 4 Series
CategoryDC Drives
LanguageEnglish

Related product manuals