Version Changes
V/f Setting range of operate value V/f: V/f>> PSx is
extended.
P634
‑303
‑403/404
‑604
Release: 2003-10-09
Hardware
This version is project-specific and only available on
request!
The Ethernet communication module is available.
Diagram
The updated connection diagrams now include the
interfaces for the Ethernet communication module:
●
P634 -403 (for 84TE case, pin-terminal
connection)
●
P634 -404 (for 84TE case, ring-terminal
connection)
Software
UCA2 Initial implementation of the UCA2 communication
protocol.
P634
‑303
‑403/404
‑605
Release: 2004-04-30
Hardware
The new hardware variants now offer, per ordering
option, additional operating thresholds for the binary
signal inputs:
●
>18 V (standard variant) (no order ext. No.)
●
>90 V (60...70% of V
A,nom
= 125...150 V) (Order
ext. No. 461)
●
>155 V (60...70% of V
A,nom
= 220...250 V) (Order
ext. No. 462)
Installation of the standard variant is generally
recommended if the application does not specifically
require such binary signal inputs with higher operate
thresholds.
Diagram
No changes.
Software
UCA2 Extension to the expanded spontaneous signaling
range. In addition, GOOSE messages and fault
transmission are now supported.
DIFF The saturation discriminator was further improved.
P634
‑304
‑403/404
Hardware
P634 A5 P634 Version History
A5-4 P634/EN M/R-42-A // P634‑311‑653