I/O NUMBER ASSIGNMENT
6.6 I/O Assignment by C Controller Setting Utility
6.6.2 Details of I/O assignment by C Controller setting utility
6 - 20
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
SETTING AND
PROCEDURES
6
I/O NUMBER
ASSIGNMENT
7
MEMORIES AND
FILES
8
INSTALLING /
UNINSTALLING
(b) Type (For C Controller module)
Select the type of the modules being mounted from the following:
• Empty (Empty slot)
• Input (Input module)
• Hi Input (Q Series high speed module)
• Output (Output module)
• I/O Mix (I/O composite module)
• Intelligent (Intelligent function module)
• Interrupt (Q Series interruption module)
If the type is not designated, the type of the actually mounted module is used.
(c) Model name
Set the mounted module model name within 16 characters.
The specified model name is not used for the C Controller module. (It is used as a
user's memo.)
(d) Points (Used with C Controller module)
To change the number of occupied I/O points of each slot, select an option from
the following:
• 0(0 point) • 16(16 points) • 32(32 points)
• 48(48 points) • 64(64 points) • 128(128 points)
• 256(256 points) • 512(512 points) • 1024(1024 points)
If the number of occupied I/O points is not designated for a slot, the one of the
actually mounted module is used.
(e) Start XY (Used with C Controller module)
When the I/O number of each slot is changed, you should designate the start I/O
number according to the change.
If Start XY is not designated for a slot, the I/O number next to the last number of
the currently designated slot is assigned.