9
UTILITY OPERATION
9.4 MELSECNET/H Utility
9 - 87
9
UTILITY OPERATION
10
FUNCTIONS AND
PROGRAMMING
11
OVERVIEW OF
MULTIPLE CPU
SYSTEM
12
MULTIPLE CPU
SYSTEM
CONFIGURATION
13
MULTIPLE CPU
SYSTEM
CONCEPT
14
COMMUNICATIONS
BETWEEN CPU
MODULES
15
PARAMETERS
ADDED FOR
MULTIPLE CPU
16
PRECAUTIONS FOR
USE OF AnS SERIES
MODULE
9.4 MELSECNET/H Utility
This section explains the operation of the MELSECNET/H utility.
The following are the precautions for use of the MELSECNET/H utility.
(1) Parameter details
Refer to the following manual for parameter details.
Q Corresponding MELSECNET/H Network System Reference Manual (PLC to
PLC network)
(2) Maximum number of concurrently applicable MELSECNET/H utilities
Up to 8 MELSECNET/H utilities can be activated and used at the same time.
(3) Precautions for writing parameters
Parameters written to the C Controller module become effective when the C
Controller module is powered off and then on or is reset.
(4) Precautions for connections from multiple MELSECNET/H utilities to the
same C Controller module
Connections can be made from multiple activated MELSECNET/H utilities to the
same C Controller module.
In this case, the MELSECNET/H utilities may have different parameters.
To make all of the MELSECNET/H utilities have the same parameters, read the
parameters from the C Controller module to each MELSECNET/H utility.
(5) Tabs available in offline mode
When the connection status of the MELSECNET/H utility is offline, only the items on
the <<Parameter setting>> and <<Target setting>> tabs can be set.
(6) Exiting Microsoft Windows
Do not terminate Microsoft Windows while the MELSECNET/H utility is running.
Exit Microsoft Windows after terminating the MELSECNET/H utility.
(7) Connection during script file execution
While script file processing is being executed (the RUN LED is flashing), access may
not be made from each utility to the C Controller module.
In such a case, connect each utility to the C Controller module after terminating the
script file processing.
Remark
For the functions added to the MELSECNET/H utility by version upgrade, refer to
Appendix 7.

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals