5.10 Setting C Controller Module Back to Factory-set State
Performing the following operation initializes the parameters files saved in the C Controller
module and sets the module back to the factory-set status.
• Executing the "Default setting" mode of the C Controller module
( This section (3))
• Formatting the standard ROM of the C Controller module ( This section (4))
• Initializing the login user information of the C Controller module ( Section 5.11.2)
(1) Applications
If any of the following symptoms is identified and the C Controller module does not
operate normally, the module can be restored to the factory-set status.
• The C Controller module does not operate normally due to execution of a user
program registered to a script file
• The IP address or login user set to the C Controller module is unknown
Figure 5.43 Operating procedure
Error occurred
Format the standard ROM.
( )
Please consult your local Mitsubishi
service center or representative,
explaining a detailed description of the
problem.
Completed
No
Yes
No
Yes
Execute the "Default setting" mode.
( )
Is C Controller module
operating normally?
Is C Controller module
operating normally?
Section 5.10 (4)
Section 5.10 (3)