l
Disable Axis: Disable axis selected
l
Enable Axis: Enable axis selected
To open the menu, right click on the drive (axis) name.
6.11 Decommissioning Procedure
WARNING: Electrical hazard - AVERTISSEMENT: risque électrique.
The DM2020 system and connected motor may present an electrical hazard if the
safety precautions are not observed, which may result in death or serious injury to
personnel, or damage to equipment.
Ø Before attempting this operation, follow the safety information and
procedures in General Hazards and Safeguards
WARNING: Mechanical hazard - AVERTISSEMENT: risque mécanique.
The DM2020 system and connected motor may present a mechanical hazard if the
safety precautions are not observed, which may result in death or serious injury to
personnel, or damage to equipment.
Ø Before attempting this operation, follow the safety information and
procedures in General Hazards and Safeguards
To disable a DM2020 (replacement, dismantling) follow the procedure below:
1.
Disconnect and lock out the mains supply voltage of the electrical panel and wait at least eight
minutes.
2. Measure for voltage at all contact points to ensure there is none present.
3.
Check that the temperatures of the heat sink and of the mechanical parts are not too high; use
gloves as needed.
4.
Loosen all connections and disconnect all connectors.
PN: L-MAM2-E-201
Moog Casella DM2020 Installation and Startup Guide
6.11 Decommissioning Procedure
118

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog DM2020 Series and is the answer not in the manual?

Moog DM2020 Series Specifications

General IconGeneral
BrandMoog
ModelDM2020 Series
CategoryDC Drives
LanguageEnglish

Related product manuals