程序检查
PROGRAM CHECK
120
5) 重新启动程序 5) Restart Program
a) 如果所测的安全距离合适并且没有干涉的风险,关闭前
门。
a) If the measured clearance is appropriate and there is no
risk of interference, close the front door.
b) 按下主轴旋转按钮
E
[ 正转 ] 或主轴旋转按钮
R
[
]
b) Press the spindle rotation button
E
[NOR] (Forward)
or spindle rotation button
R
[REV] (Reverse).
[ 主轴在停止前以初始转速旋转 ] [Spindle rotation at the original speed before stopping]
c) 检查程序直到结束。 c) Check the program up to the end.
6) 程序检查后 6) After Program Check
a) 程序检查后,必要时修改程序。 a) After the program check, modify the program if
necessary.
b) 如果重新启动程序没有发现问题,程序完成后将移位数
据重设为初始值。
b) If there are no problems found in the restarted program,
reset the shifted data to its original value after the
completion of the program.
1. 使用光标移动键将光标移动到要输入数据的
‘Z’处。
1. Move the cursor to Z of COMMON where the
data is to be input using the cursor control keys.
2. 输入 100.0 2. Input “ 100.0 .
2 注意 2 NOTE
确认输入值的符号正确。 Make sure the sign for the entered value is correct.
3. 按下 [+ 输入 ] 3. Press the [+ INPUT].
2 注意 2 NOTE
确保按下 [+ 输入 ] 如果按下
[
(Enter) /
\
( 输入 )
,通过数据输入键输入的值为工件平移数据( Z 轴)。
Make sure to press the [+ INPUT]. If the
[
(Enter) key/
\
(INPUT) key is pressed, the value that was input with
data entry keys is input for the work shift data (Z-axis).
模式选择按钮
a
[MEM] ( 存储器 ) D 按下自动运行按钮
q
[ 开始 ]
[ 程序重新启动。]
Mode selection button
a
[MEM] (Memory) D Press the
automatic operation button
q
[START] (Start).
[Program restarts.]
功能选择键
o
( 补偿 ) D [ 工作坐标 ]
[ 显示 工件补偿 屏幕 ]
Function selection key
o
(OFFSET) D [WORK OFFSET]
[The WORK OFFSET screen is displayed]