EasyManuals Logo

Motion Control Engineering 2000 User Manual

Motion Control Engineering 2000
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
F3: System Mode
5-65
5
10. If the Extra Features Menu Option “Analog Load Weigher?” is set to K-TECH, the car
will move to the bottom floor, record the full car value and then move up, stopping at
each floor to record the full car value. When the top floor has been reached, the car will
move back to the floor at which the Analog Load Weigher Learn Function was begun
and the computer will display the scrolling message:
FULL CAR LEARN PROCESS COMPLETED. PRESS S TO CONT.
11. If the Extra Features Menu Option “Analog Load Weigher?” is set to MCE, the car will
learn the full car value and then display the message:
FULL CAR LEARN PROCESS COMPLETED. PRESS S TO CONT.
12. Press the S push button, place the F3 switch in the down position and take the car off of
Independent service.
13. To verify that the Load Weigher Learn Function has been performed successfully, place
the F8 switch in the up position. With the test weights in the car, the following should
be displayed:
CURRENT LOAD = 1OO%
14. If the Load Weigher Learn Function has not been performed successfully, the following
will be displayed:
CURRENT LOAD = NOT LEARNED
15. The Load Weigher Learn Function (empty or full values) may be aborted at any time by
pressing the N push button. The computer will display the message:
LEARN PROCESS ABORTED... PRESS S TO CONT.
16. When the S push button is pressed the computer displays the scrolling message:
ANALOG LOAD WEIGHER LEARN FUNCTION. PRESS S TO START
17. At this point you may exit System Mode by placing the F3 switch in the down position,
or you may re-start the learn function by moving the car back to the floor where the test
weights are located and press S to start (go to step 4).
18. If the empty car values have been learned but the full load learn function was aborted,
you need not re-learn the empty car values. When the message
READY TO LEARN EMPTY
CAR VALUES
is displayed, press the N push button. The computer will display:
READY TO LEARN FULL CAR VALUES? PRESS S TO START.
19. Press the S push button to begin learning the full car values (go to step 10).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering 2000 and is the answer not in the manual?

Motion Control Engineering 2000 Specifications

General IconGeneral
BrandMotion Control Engineering
Model2000
CategoryController
LanguageEnglish

Related product manuals