Motion 2000 TSSA Description
1-12 Manual # 42-02-1P21
Operating Mode Descriptions
Available operating modes are configured when the car is installed. Not all modes are available
on all cars. This section describes controller operating modes, including:
Automatic Operation
Inspection Operation
Attendant Service Operation
Independent Service Operation
Sabbath Operation
Emergency Medical Operation
Hospital Service Operation
Fire Service Operation
Emergency Power Operation
•Car Recall
Capture for Test
•Test Mode
Automatic Operation
Automatic operation is the normal, default elevator operating mode. In this mode, cars are
accepting hall calls and servicing car calls as determined by Basic Features Menu and other
operating menu selections. Please refer to “Basic Feature Menu Options” on page 5-17.
Mode Entry
Machine Room Inspection Mode Switch: Normal
•Test Switch: Normal
Car Door Bypass: Off
Hoistway Door Bypass: Off