The Computer
5-20 Manual # 42-02-1P21
Fire Service Menu Options
FIRE SERVICE OPERATION? If Fire Service operation is not required, then this
option should be set to NO. Otherwise, if set to YES, the options below will appear on the LCD
display.
FIRE PHASE 1 MAIN FLOOR Any landing can be selected to be the Main Fire Return
Floor for Fire Service.
FIRE PHASE 1 ALT. FLOOR Any landing can be selected to be the Alternate Fire
Return Floor for Fire Service.
FIRE SVCE. CODE The Fire Service Operation will conform to the selected fire service
code. The fourteen different codes to choose from are:
1. CHICAGO (OLD) 9. CITY OF HOUSTON
2. VET ADMIN (Veterans' Administration) 10. AUSTRALIA
3. NYC RS-18 11. CITY OF DETROIT
4. ANSI A17.1 -89> 12. MASSACHUSETTS
5. CALIF. TITLE 8 13. ANSI A17.1 85 - 88
6. HAWAII 14. CITY OF DENVER
7. CSA B44-M90 15. CHICAGO 2001
8. 34 PA CODE, CH. 7 16. ANSI A17.1-2000
FIRE PHASE I 2ND ALT. FLOOR Detroit Fire Code only. Any landing may be the 2
nd
alternate fire return floor. Select None if there is no second alternate return floor.
WILL THIS CAR RUN ON PH2? This car is allowed to run on Fire Phase II if this
option is set to YES.
BYPASS STOP SW. ON PHASE 1? This option was added to keep the stop switch
from being bypassed on Fire Phase I. With this option set to NO, the CSB output will not come
ON as the car is returning on Fire Phase I.
HONEYWELL FIRE OPERATION? This option is only available if the FIRE SVCE.
CODE option is set to AUSTRALIA (see “FIRE SVCE. CODE” on page 5-20). If this option is set
to YES then the Australia fire code will conform to Honeywell’s requirements. If this option is
set to NO then the controller will conform to standard Australia code.
NYC FIRE PHASE 2 AND ANSI 89? This option is only available if the FIRE SVCE.
CODE option is set to ANSI A17.1 89 (see “FIRE SVCE. CODE” on page 5-20). If this option is
set to YES then the ANSI A17.1 89 Fire Code will conform to New York City Fire Code require-
ments when on Fire Phase 2. If this option is set to NO then the controller will conform to stan-
dard ANSI A17.1 89 Fire Code.
WHITE PLAINS, NY FIRE CODE? This option is only available if the FIRE SVCE.
CODE option is set to ANSI17.1 89 (see “FIRE SVCE. CODE” on page 5-20). The city of White
Plains requires that if fire phase one is still in effect, the car can exit fire phase two regardless of
the position of the doors. Setting this option to YES will comply with this requirement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering 2000 and is the answer not in the manual?

Motion Control Engineering 2000 Specifications

General IconGeneral
BrandMotion Control Engineering
Model2000
CategoryController
LanguageEnglish

Related product manuals