Operating Mode Descriptions
1-19
1
Capture for Test (Pretest)
Pretest is used to capture the car in preparation to using Test mode.
• When this input is activated, the car will stop responding to hall calls and disable its gongs
but continue to service car calls.
• The intent of the input is to allow maintenance personnel to capture the car while causing
as little disruption to service as possible.
• Enter Pretest mode by placing the TEST/NORMAL/PRETEST switch on the HC-CTL-2
board in the PRETEST position. (The car will not enter Pretest if Inspection is active.)
Test Mode
Test mode allows the car to be run without operating the doors. When Test mode is active, door
open circuitry is deactivated.
• Enter Test mode by placing the TEST/NORMAL switch on the HC-CTL-2 board in the
TEST position. (The car will not enter Test mode if Inspection is active.)
• When Test mode is active, the controller LCD will display TEST MODE.