The Computer
5-54 Manual # 42-02-1P21
Additional Car Options Menu
HOISTWAY ACCESS? (YES/NO) Set to YES if job has Hoistway Access operation.
TOP ACCESS? (F/R) Set to the riser in which the hall access switch is located.
BOTTOM ACCESS? (F/R) Set to the riser in which the hall access switch is located.
NUMBER OF MOTOR STARTERS (1-3) - Indicates the total number of starters for this
car.
MIN. NUMBER OF MOTORS (1-3) - Set the minimum number of starters required to
run. This option is only available for multi-starter controllers.
SOFT-STOP TIMER (NONE / 0.1-1.0 sec) - The soft-stop timer will cause the pump to
continue to operate for the programmed amount of time after the elevator has stopped to allow
the valves to fully close.
STARTER #1 TYPE: (WYE-DELTA / ACROSS THE LINE / SOLID STATE) - Select the
appropriate type of starter. Applicable to starter #1.
STARTER #2 TYPE: (WYE-DELTA / ACROSS THE LINE / SOLID STATE / NONE) -
Select the appropriate type of starter. Applicable to starter #2.
STARTER #3 TYPE: (WYE-DELTA / ACROSS THE LINE / SOLID STATE / NONE) -
Select the appropriate type of starter. Applicable to starter #3.
Y-D TRANSFER TIMER (1.0-8.0 sec) - Represent the amount of time that the motor
will run with a Wye contactor before switching to the Delta contactor. Set this option only for
starters with WYE-DELTA configuration.
UP TO SPEED TIMER (1.0-8.0 sec) - Represent the amount of time that the controller
will wait to allow the motor to accelerate to nominal speed. Set this option only for starters with
ACROSS THE LINE or SOLID STATE configuration.
Y-D OPEN TRANSN. TIMER (50-500 msec) - Represent the time delay in picking the
Delta contactor after the dropping of the Wye contactor. Set this option only for starters with
WYE-DELTA configuration.
M CONTACTOR INSTALLED? (YES/NO) - Set this option to YES only for starters with
M Contactors. Option not available for SOLID STATE starters.
STARTER CONFIG: (SEQUENTIAL / SIMULTANEOUS) - This option is only available
for multi-starter Hydraulic systems. If the SEQUENTIAL option is set the starters will start in a
sequential fashion to reduce inrush current. If the SIMULTANEOUS option is set then all start-
ers in the system will start at the same time.
VALVE TYPE: (STANDARD / PILOT RELAYS / TKE / DOVER) - This option indicates
the type of valve used for this installation.