3-51 NWA-033623-001 Rev.8.1
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICES
08
NOTE 1: When CM08>268 is set to 0 (restricted), set CM08>269 to 0 (station base).
NOTE 2: CM08>281 is required for Hotel printer.
Continued on next page
: Default
BASIC SERVICE SETTING DATA
268 Call termination to My Line while the station user makes a call
with a Sub line or trunk line on Multiline Terminal NOTE 1
0
1
Restricted
Allowed
269 Busy indication on BLF of large type DESKCON, DSS Con-
sole or Multiline Terminal by station base or extension base
NOTE 1
0
1
Station base
Extension base
270 Voice Call when calling Multiline Terminal set to Voice First
from single line telephone or Multiline Terminal without LCD
0
1
Not provided (Busy Tone)
To provide
274 Line lockout indication on DSS Console 0
1
Available
Not available
281 Maid Identification number used for Maid Status NOTE 2 0
1
Available
Not available
289 Room Cutoff 0
1
Not Allowed
To allow
294 MW lamp indication on Multiline Terminal to which Message
Waiting/Message Reminder is set
0
1
Flashing (60 IPM)
Steady lighting