Maintenance
424
M4100 Series Managed Switch
The Login screen displays.
5. Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
6. Click the Login button.
The web management interface menu displays.
7. Select Maintenance
Troubleshooting Traceroute IPv4.
8. Use IP Address/Hostname to enter the IP address or host name of the station you want the
switch to discover path.
The initial value is blank. The IP address or host name that you enter is not retained
across a power cycle.
9. Optionally
, configure the following settings:
• Probes Per Hop. Enter the number of probes per hop.
The initial value is the default.
The probes per hop you enter is not retained across a power cycle.
• MaxTTL. Enter the maximum
TTL for the destination. The initial value is default value.
The MaxTTL you enter is not retained across a power cycle.
• InitTTL. Enter the initial
TTL to be used. The initial value is default value. The InitTTL
you enter is not retained across a power cycle.
• MaxFail. Enter the maximum number of failures allowed in the session.
The initial
value is default value. The value you enter is not retained across a power cycle.
• Interval (secs). Enter the
Time between probes in seconds. The initial value is default
value. The interval you enter is not retained across a power cycle.