E Series Automated Dispensing System
71www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Calibrating the Tip Height (continued)
Recalibrate the Tip (Needle Adjust)
PREREQUISITES
The tip height is calibrated. Refer to “Set a Calibration Point (Initial Setup for Needle Adjust)” on page70.
# Key Press Step Teach Pendant Display
1
> >
• Press F1.
• MOVE UP / DOWN to NEEDLE ADJUST.
• Press ENTER.
[PROGRAM MENU] 1/1
01 Teach/Run
02 Program List
03 Reset Counter
04 Program Offset
05*Needle Adjust
06 Auto Needle Adjust
2
• Press ENTER.
The dispensing tip moves to the user-
dened calibration point.
NOTE: The tip will be 5 mm (0.2") higher
than the calibrated point to prevent
possible crushing of the tip.
Needle Adjust
------------------------------
Press [ENTER] to begin
------------------------------
3
>
• Jog the tip until it is centered over the
calibration point.
• Press ENTER.
The system adjusts the dispense
program to the recalibrated tip height.
Needle Adjust
------------------------------
Jog tip over calibration point
------------------------------
[ENTER]