G-19
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
G-12 UPC/EAN
G
G-12-3 Separator Status (UPC/EAN)
When set to Required, both the main and the supplemental symbols must be read.
For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as
the UPC separator character. Then the data is displayed as:
MAIN * SUPPLEMENTAL.
•Note: Under no circumstances will the supplemental symbol data be sent without a main symbol.
•Note: If additional symbols—other than the main or supplemental—will be read in the same read cycle, Number of
Symbols should be set accordingly.
•Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command will return the cur-
rent settings, including the separator character comma which appears after the separator status comma.
Either 2 character or 5 character supplementals will be considered valid.
Only two character supplementals will be considered valid.
Only five character supplementals will be considered valid.
Required
G-12-3 Separator Status (UPC/EAN)
Usage: Allows users to distinguish between the main and Supplemental symbols.
Definition: A character can be inserted between the standard UPC or EAN symbology
and the supplemental symbology when Supplementals is set to Enabled
or Required.
Serial Cmd: <K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
G-12-4 Separator Character (UPC/EAN)
Usage: As required by the application.
Definition: Allows the user to change the separator character from a comma to a new
character.
Serial Cmd: <K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default: , (comma)
Options: Any ASCII character.
G-12-5 Supplemental Type (UPC/EAN)
Usage: As required by symbology used in application.
Definition: Allows the user to select 2 character or 5 character supplements, or both.
Serial Cmd: <K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default: Both
Options: 0 = Both 1 = 2 characters only 2 = 5 characters only
Both
2 Characters Only
5 Characters Only