I-15
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
I-7 ISO/IEC 15416 Symbol Quality Output
I
I-7-8 Modulation
I-7-8 Modulation
Definition: Modulation is calculated and graded for each scan and provided for the
overall grade calculation in accordance with the ISO 15416 specifica-
tion. The parameter grade and value provided for output is an average
value for each measured scan over the entire symbol.
When enabled, the Modulation is attached to the symbol output data as
a value.
Serial Cmd: <K726, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects, decod-
ability, quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
I-7-9 Defects
Definition: Defects are calculated and graded for each scan and provided for the
overall grade calculation in accordance with the ISO 15416 specifica-
tion. The parameter grade and value provided for output is an average
value for each measured scan over the entire symbol.
When enabled, the Defects are attached to the symbol output data as a
value.
Serial Cmd: <K726, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects, decod-
ability, quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
I-7-10 Decodability
Definition: Decodability is calculated and graded for each scan and provided for
the overall grade calculation in accordance with the ISO 15416 specifi-
cation. The parameter grade and value provided for output is an aver-
age value for each measured scan over the entire symbol.
When enabled, the Decodability is attached to the symbol output data
as a value.
Serial Cmd: <K726, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects, decod-
ability, quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
I-7-11 Quiet Zone
Definition: Quiet Zone is not an individually processed parameter within the ISO
15416 specification, but it is evaluated as a part of the ISO graded
decode parameters feeding into the overall grade. Quiet Zone is pro-
vided here as average scan result where a passing scan receives an
A/4.0 grade and a fail receives an F/0.0.
When enabled, the Quiet Zone is attached to the symbol output data as
a value.
Serial Cmd: <K726, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects, decod-
ability, quiet zone>
Default: Disabled
Options: 0 = Disabled 1 = Enabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MicroHAWK V320-F and is the answer not in the manual?

Omron MicroHAWK V320-F Specifications

General IconGeneral
BrandOmron
ModelMicroHAWK V320-F
CategoryBarcode Reader
LanguageEnglish

Related product manuals