Adjustment
93
13.11 Height of the needles
Rule
There should be a clearance of 4 mm between the needle points and the front edge of
the loading plate 1 when the needles are extended.
Remove the cover plate of the loading plate 1.
Extend the needles.
Adjust the needles (screws 2) according to the rule.
The cover plate remains dismantled for additional settings.
Fig. 13 - 26
1
4 mm
2