Voltage may be present on terminals. Follow warnings for operation and servicing.
Maintain product repair capability for at least five years after original shipment.
Details Ls, Lp, Cs, Cp, Rs, Rp, and |Z| measurement ranges.
Basic LCR accuracy is 0.1%, Basic DQ is ±0.001.
10 User Selectable Test Frequencies: 50Hz to 100kHz.
240x64 LCD display, IEEE-488 and Handler interfaces.
Operating: 10°C to +40°C, 10-90% RH. Storage: 0°C to +50°C, 10-90% RH.
Lists items included with the instrument such as AC Power Cord and Instruction Manual.
Lists optional accessories like test fixtures and cable sets.
Instructions for safe operation, grounding, lead connection, and avoiding hazards.
Explains safety symbols and warning messages like DANGER.
Describes the 1730T LCR Meter's capabilities and parameters.
Instructions for powering on the instrument and initial warm-up.
Illustrates the MEAS DISPLAY screen and menu functions for navigation.
Steps to set test parameters like frequency, voltage, and measurement parameters.
Procedure to zero test leads using OPEN and SHORT configurations.
Illustrates connecting the 1730T to a DUT using Kelvin Clips cable.
Steps to perform a measurement: Press MEAS DISPLAY, connect DUT, press TRIGGER, record.
Inspect shipping carton and instrument for damage upon receipt.
Details the 1730T LCR Meter's capabilities, parameters, accuracy, and interfaces.
Identifies front panel controls and indicators with their descriptions and functions.
Lists rear panel controls and connectors with their types and functions.
Provides physical dimensions and recommends optimal viewing angle and airflow.
Details power source requirements, fuse ratings, and grounding.
Step-by-step guide for replacing the instrument fuse.
Defines measurement unit prefixes, accuracy, and basic terms like Binning and Capacitor.
Defines capacitance, capacitive reactance, and related terms.
Defines AC and DC current.
Explains series and parallel equivalent circuits for DUTs.
Defines frequency and ground reference for measurements.
Describes Handler, IEEE-488, RS232, and Scanner interfaces.
Defines High Limit and Low Limit for test pass/fail criteria.
Defines repeatability, reproducibility, resolution, and source impedance.
Instructions for startup and accessing SYSTEM SETUP/CONFIG controls.
Configures VM/IM display and constant source impedance settings.
Configures average time, cable length, and beeper loudness.
Locks out front panel operations except TRIGGER key. Can be set ON or OFF.
Configures integer cycle, display contrast, and audible alarm sound mode.
Configures alarm type, handler mode, and GPIB End of String code.
Configures GPIB address, trigger delay, and trigger edge selection.
Links to 1320 Bias Source and runs instrument status check.
Describes the MEAS DISPLAY screen and its parameter pages.
Sets test frequency, voltage, and selects primary/secondary measurement parameters.
Lists measurement parameters and describes DCR measurement.
Explains transformer turns ratio measurement using test fixture.
Illustrates transformer test fixture and its connection to the LCR meter.
Selects measurement range as AUTO or HOLD.
Programs measurement speed and details accuracy specifications.
Provides accuracy values for different parameters and voltage levels.
Details accuracy formulas for L, C & R, D & Q, and R (ESR, EPR).
Presents conversion charts for LC to Z, C to Z, and L to Z.
Provides accuracy formulas for DCR and Turns Ratio.
Configures trigger mode and enables/disables DC bias voltage.
Enables/disables binning and compare functions for component sorting.
Explains COMPARE settings: ON-VAL, ON-Δ, ON-Δ%.
Connects to 1320 Bias Current Source for external DC bias current.
Enables/disables bias current function and sets current level from external source.
Accesses MAIN INDEX for Binning, Compare, Correction and sets binning parameters.
Views bin counts and configures speed, trigger, and range for binning.
Describes sorting components using % tolerance or absolute value limits.
Stores test parameters, bin settings, and compare settings to memory locations.
Recalls stored test parameters, bin settings, and compare settings from memory.
Sets up comparison tests with nominal, high, and low limits.
Performs automatic offset for lead/fixture effects (OPEN/SHORT).
Illustrates menus for performing an OPEN correction.
Illustrates menus for performing a SHORT correction.
Instructions for performing short correction measurement.
Illustrates connecting the 1730T LCR Meter to a single DUT using Kelvin Clip Cable.
Lists available test leads and fixtures with part numbers and figures.
Shows connection of the axial/radial component test fixture.
Shows connection of the axial/radial remote test fixture.
Illustrates connection of component tweezers cable lead set.
Illustrates BNC to BNC test cable lead sets.
Illustrates the SMD test fixture and its connection.
Illustrates the transformer test fixture connection.
Illustrates connection of the 1730T to the 1320 DC Bias Current Source.
Steps to verify instrument setup and initiate a test measurement.
Details the IEEE-488 interface and its connection.
Shows the IEEE-488 interface pin configuration and designation.
Lists IEEE-488 pin designations by pin number, signal name, and function.
Defines IEEE-488 function codes and messages the instrument responds to.
Lists IEEE-488 commands accepted by the instrument.
Explains the 8-bit Status Byte Register and its assignments.
Describes the 8-bit Standard Event Status Register and its assignments.
Details Operation Status and Questionable Status registers.
Illustrates programming commands accepted by the IEEE-488 interface.
Lists IEEE-488 commands for Sense, Source, System, Trigger, and Binning functions.
Explains the Root format for IEEE-488 commands and parameter syntax.
Details IEEE commands including format, parameter, return value, and function.
Terminates a trigger in process and resets the trigger.
Sets or queries the primary measurement parameter.
Sets or queries the secondary measurement parameter.
Commands for beeper condition, state, and limit values.
Sets or queries if the Compare function is ON or OFF.
Commands for upper limit, math expressions, and state.
Commands for VM/IM state, cable length, and nominal data.
Sets or queries the LCD display state and screen/page shown.
Sets or queries which screen or page of MEAS DISPLAY is shown.
Gets measurement results from the INITiate function.
Commands for data format, initiation, averaging, and correction procedures.
Commands for correction data, impedance aperture, and range settings.
Sets or queries equivalent circuit mode and transformer measurement mode.
Commands for source frequency/voltage, system settings, and trigger control.
Commands for system errors, handler, integration, key lock, preset, and version.
Commands for trigger delay, source, and setting upper BIN limits.
Commands for setting lower BIN limits, AUX values, and nominal values.
Commands to set Binning function ON/OFF and retrieve binning results.
Example of programming bin limits for a binning operation.
Example of programming nominal, high, and low limits for a compare operation.
Provides a sample Basic program for the 1730T LCR Meter.
Details the Handler interface and its connection via a 50-pin connector.
Illustrates the handler interface pin configuration.
Illustrates the trigger function timing.
Illustrates the handler interface connection to the 1730T main board.
Illustrates the input signals for the Handler interface.
Illustrates a basic example of an external trigger connection.
Lists pin assignments for handler interface during binning operation.
Lists pin assignments for handler interface during compare operation.
Details connectors for bias voltage (or current) applications.
Provides DC bias current and source impedance data.
Provides DC bias voltage and source impedance data.
Details warranty, quality of materials, and application assistance.
Instructions for returning an instrument for service, including RMA number.
Describes factory calibration and recommended annual verification.
Outlines the procedure to verify the 1730T LCR Meter's performance and accuracy.
Details instrument setup and connections for verification standards.
Provides a data sheet for recording verification measurements for various standards.
Verification data for various inductance and capacitance standards.
Verification data for various capacitance standards (10nF to 100nF).