4.3 Transport of the Components
Ambient and operating conditions-Transport
Description Symbol Unit Value
Temperature range
T
a_tran
-25…70
Relative humidity % 5…95
Absolute humidity
g/m
3
1…60
Climate category (IEC 721) 2K3
Moisture condensation not allowed
Icing not allowed
Tab. 4-1: Transport conditions
4.4 Storage of the Components
Damage to the components caused by long
storage periods!
CAUTION
Some components contain electrolytic capacitors which may deteriorate during
storage.
When storing these components for a long period of time, remember to operate
them once a year:
Run frequency converter EFC 3600 under power U
LN
for at least 1 hour.
For more information of electrolytic capacitors, please contact service.
Ambient and operating conditions-Storage
Description
Symbol Unit Value
Temperature range
T
a_store
-20…60
Relative humidity % 5…95
Absolute humidity
g/m
3
1…29
Climate category (IEC 721) 1K3
Moisture condensation not allowed
Icing not allowed
Tab. 4-2: Storage conditions