1.4.3 Transport of the Components
Ambient and operating conditions-Transport
Description Symbol Unit Value
Temperature range
T
a_tran
-25…70
Relative humidity % 5…95
Absolute humidity
g/m
3
1…60
Climate category (IEC 721) 2K3
Moisture condensation not allowed
Icing not allowed
Tab. 1-2: Transport conditions
1.4.4 Storage of the Components
Damage to the components caused by long
storage periods!
CAUTION
Some components contain electrolytic capacitors which may deteriorate dur‐
ing storage.
When storing these components for a long period of time, operate them once
a year for at least 1 hour with power on:
Fv with mains voltage U
LN
FELB with DC bus voltage U
DC
Ambient and operating conditions-Storage
Description Symbol Unit Value
Temperature range
T
a_store
-25…55
Relative humidity % 5…95
Absolute humidity
g/m
3
1…29
Climate category (IEC 721) 1K3
Moisture condensation not allowed
Icing not allowed
Tab. 1-3: Storage conditions
DOK-RCON02-FV*********-IB08-EN-P Bosch Rexroth AG 19/259
Rexroth Frequency Converter Fv
Introduction

Table of Contents

Other manuals for REXROTH Fv Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH Fv Series and is the answer not in the manual?

REXROTH Fv Series Specifications

General IconGeneral
BrandREXROTH
ModelFv Series
CategoryDC Drives
LanguageEnglish

Related product manuals