b0.11 Parameter groups to be read and set
0 b
1 b, S
2 b, S, E
3 b, S, E, H
Tab. 7-4: Parameter filter range
b0.12
Heat sink temperature Factory default
Measured
value
Setting range 25...100 °C Minimum unit 1
● Displays the power module (IGBT) and heat sink temperature (in °C).
– '――' is displayed when the temperature is lower than 25 °C.
– Overheat protection is activated at 85 °C.
b0.13
Total running time Factory default 0
Setting range 0...65,535 hours Minimum unit 1
● Displays the total running time of the frequency converter.
b0.13 will not be reset with ‘Restore factory default’ b0.02.
b0.14
Firmware version Factory default –
Setting range Read-only Minimum unit –
b0.15
Reserved Factory default 0
Setting range 0, 1 Minimum unit 1
Group b1: Basic parameters
b1.00
Frequency setting mode Factory default 0
Setting
range
0: Set by operating panel potentiometer
1: Set by operating panel
2: Set by analog inputs
3: Set by pulse frequency
4: Set by digital inputs UP / DOWN
5: Set by communication
Minimum unit 1
● 0: Set by operating panel potentiometer
Set the frequency by adjusting the operating panel’s potentiometer.
● 1: Set by operating panel
– Use the value of parameter b1.04 as the set frequency.
– Use <▲>and <▼> keys to change the output frequency value when
the frequency converter is in run mode.
DOK-RCON02-FV*********-IB08-EN-P Bosch Rexroth AG 105/259
Rexroth Frequency Converter Fv
Parameter Settings